Steinbach Steinbach

Heat pump Waterpower 5000

049202
Art.
  • LCD Display
  • Titan heat exchanger - suitable for salt water pools
  • Installation at any time later possible
  • Heating and cooling function
  • Performance strong and environmentally friendly R32 gas
  • Bypass set (Art. No. 060045) recommended

Sold Out

The selected product is currently not available. As soon as the product is on stock, we will send you an E-mail.

€899.00
including VAT
In stock
From € 49,- free shipping
Return free of charge

Product information

Pool water perfectly balanced for your well-being, this allows you to enjoy the Heat pump Waterpower 5000! For even more efficient use of Steinbach heat pumps, we also recommend our Steinbach Bypass Set (item no. 060045). With the help of the Steinbach Bypass Set, the water flow and the water circuit can be regulated individually.*Our Steinbach heat pump Waterpower 5000 is also suitable for saltwater pools due to the titanium heat exchanger installed. The salt concentration must not exceed 0.50 % (corresponds to 5 g/l or 5,000 ppm).

  • *Incl. a Titan heat exchanger - suitable for salt water pools
  • Performance strong and environmentally friendly R32 gas
  • Can be fitted retrospectively
  • Integrated control with LCD display
  • Cooling function for no extra charge
  • Minimal maintenance required

 

Water capacity: 30.000 l
Minimum water flow rate: 3.000 l/h
Dimension: 70 x 26,5 x 51,5 cm
Salt water suitable: yes
Connection size: Ø 32/38 mm
Heating power*: 5.100 W
Input power heater*: 840 W
Heating input current*: 3,60 A
Cooling possible: yes
Cooling capacity*: 3.400 W
Cooling input power*: 1.150 W
Input current cooling*: 5,20 A
Input power maximum: 1.200 W
Input current maximum: 5,80 A
Power supply**: 220-240V~ / 50Hz
Performance coefficient COP heating: 6,10
Energy efficiency ratio EER cooling: 3,70
Protection class: I
Protection class: IPX4
Sound pressure level (10 m): 39 dB(A)
Suction pressure nominal: 0,70 MPa
Suction pressure maximum: 15 MPa
Delivery pressure nominal: 3,00 MPa
Maximum discharge pressure: 4,30 MPa
Refrigerant: R32
Refrigerant charge maximum: 320 g
Global Warming Potential GWP: 675
CO2 equivalent: 0,22 t
Water temperature: 5°C - 45°C
Ambient temperature: 5°C - 50°C
Timer present: no
Cable length to unit: 1,45 m


*variable - depending on the environmental conditions.
**single-phase alternating current

Free shipping
12 Control/display
€76.90
including VAT
39 Fan motor for 049202
€48.90
including VAT, plus shipping costs
40 Fan for 049202
€13.90
including VAT, plus shipping costs
€28.90
including VAT, plus shipping costs
Free shipping
€87.90
including VAT
€8.99
including VAT, plus shipping costs
€8.99
including VAT, plus shipping costs
€8.99
including VAT, plus shipping costs
€37.90
including VAT, plus shipping costs
€7.99
including VAT, plus shipping costs
€34.90
including VAT, plus shipping costs
€7.99
including VAT, plus shipping costs
At the moment this product is not available
€20.90
including VAT, plus shipping costs

FAQs from category Heat pumps:

The liquid in the pressure gauge is not water, but a stabilising liquid (similar to glycerine). This liquid causes the pointer to remain stationary even under strong vibrational loads (which occur with heat pumps).

This is condensation water that drips off automatically. 

Use the 50 mm / 38 mm adapter supplied. You can attach a 38 mm swimming pool hose using hose clamps and Teflon tape.

All Steinbach air heat pumps are equipped with a titanium heat exchanger and can be used for salt water pools with a salt concentration of up to 0.5 %.

Yes, the air source heat pump is always integrated into the existing filter circuit after the filter system. Note that the filter pump has the required minimum water flow rate.

The most powerful heating is of no use if the following factors are not taken into account: Pools with a cover, e.g. solar cover, have a lower heat loss. Insulated pools have a much lower heat loss than pools without insulation. The filter runtime and thus the operating time of the additional heating must be taken into account. Wait 24 - 48 h until the set temperature is reached. The higher the temperature difference between the pool water and the outside temperature, the higher the energy loss. Take external influences into account. Heat loss can occur due to cold or strong wind. Minimise the flow rate of the heat pump within the minimum water flow rate of (depending on the heat pump model*) , so that the residence time in the heat pump is longer. *4 m³/h-6 m³/h = 049202, 6 m³/h-8 m³/h = 049207

All Steinbach heat pumps have a sound pressure level* of < 70 dB(A).

*The emission volume is comparable to a large household appliance.

EEb means that the water flow is insufficient. Raise the water flow using a bypass kit that regulates the heat pump.

EEc means that the ambient temperature is below 15°. Wait until the ambient temperature increases. In the cold seasons autumn/winter, the heat pump must be dismantled.

The water that forms in the heat pump is called condensate. This is the moisture contained in the air that condenses when it comes into contact with certain cold components inside the heat pump. The more humid the outside air, the more condensate the heat pump produces (your unit may produce several litres of water per day). The water collects at the bottom of the heat pump and escapes through the drain provided.

Accessories
Other customers also purchased

Symbol photos

The pictures shown are just for reference, the actual product may differ.