up to -40 %
Steinbach Steinbach

Heat pump Waterpower

Art.
  • LCD Display
  • Titan heat exchanger - suitable for salt water pools
  • Heating and cooling function
  • Installation at any time later possible
  • Bypass set (art. no. 060045) recommended

Sold Out

The selected product is currently not available. As soon as the product is on stock, we will send you an E-mail.

* Mandatory Field

from €563.40 RRP €939.00
incl. VAT, Free shipping
Only %1 left

Only items left in stock

The minimum order quantity is 1

Product information

Thanks to a Waterpower heat pump with heating and cooling function, you can adjust the water temperature perfectly to your well-being. The heat pump impresses with minimal maintenance, integrated control via LCD display and a cooling function at no extra charge. Due to the built-in titanium heat exchanger, the heat pump is also ideally suited for salt water pools. The salt concentration must not exceed 0.50 % (corresponds to 5 g/l or 5,000 ppm).
For an even more efficient use of the heat pump, we recommend our Steinbach bypass set (art. no. 060045). With this set, you can regulate the water flow and the water circuit individually.

    Water capacity: 55.000 l
    Minimum water flow rate: 3.000 l/h
    Dimension: 99 x 32 x 54 cm
    Salt water suitable: yes
    Connection size: D 50/Ø 38 mm
    Heating power*: 8.500 W
    Input power heater*: 1.450 W
    Heating input current*: 7,30 A
    Cooling possible: yes
    Cooling capacity*: 6.000 W
    Cooling input power*: 1.650 W
    Input current cooling*: 8,20 A
    Input power maximum: 1.950 W
    Input current maximum: 8,90 A
    Power supply**: 220-240V~ / 50Hz
    Performance coefficient COP heating: 6
    Energy efficiency ratio EER cooling: 3,70
    Protection class: I
    Protection class: IPX4
    Flow sensor: yes
    Sound pressure level (10 m): 42 dB(A)
    Suction pressure nominal: 0,70 MPa
    Suction pressure maximum: 15 MPa
    Delivery pressure nominal: 3,00 MPa
    Maximum discharge pressure: 4,30 MPa
    Refrigerant: R32
    Refrigerant charge maximum: 650 g
    Global Warming Potential GWP: 675
    CO2 equivalent: 0,44 t
    Water temperature: 5°C - 45°C
    Ambient temperature: 5°C - 50°C
    Timer present: no
    Cable length to unit: 1,45 m


    *variable - depending on the environmental conditions
    **single-phase alternating current

    12 Control/display
    €76.90
    incl. VAT, Free shipping
    41 Fan for 049207
    €13.90
    incl. VAT, excl. shipping
    €34.90
    incl. VAT, excl. shipping
    €23.90
    incl. VAT, excl. shipping
    At the moment this product is not available
    €33.90
    incl. VAT, excl. shipping
    €4.99
    incl. VAT, excl. shipping
    €7.99
    incl. VAT, excl. shipping
    €14.90
    incl. VAT, excl. shipping
    At the moment this product is not available
    €7.99
    incl. VAT, excl. shipping
    €8.99
    incl. VAT, excl. shipping
    €8.99
    incl. VAT, excl. shipping
    €8.99
    incl. VAT, excl. shipping
    €87.90
    incl. VAT, Free shipping
    €28.90
    incl. VAT, excl. shipping
    12 Control/display
    €76.90
    incl. VAT, Free shipping
    39 Fan motor for 049202
    €48.90
    incl. VAT, excl. shipping
    40 Fan for 049202
    €13.90
    incl. VAT, excl. shipping
    €34.90
    incl. VAT, excl. shipping
    €20.90
    incl. VAT, excl. shipping
    At the moment this product is not available
    €4.99
    incl. VAT, excl. shipping
    €32.90
    incl. VAT, excl. shipping
    €7.99
    incl. VAT, excl. shipping
    €14.90
    incl. VAT, excl. shipping
    €7.99
    incl. VAT, excl. shipping
    €8.99
    incl. VAT, excl. shipping
    €8.99
    incl. VAT, excl. shipping
    €8.99
    incl. VAT, excl. shipping
    €87.90
    incl. VAT, Free shipping
    €28.90
    incl. VAT, excl. shipping

    FAQs from category Heat pumps:

    The liquid in the pressure gauge is not water, but a stabilising liquid (similar to glycerine). This liquid causes the pointer to remain stationary even under strong vibrational loads (which occur with heat pumps).

    This is condensation water that drips off automatically.

    Use the 50 mm / 38 mm adapter supplied. You can attach a 38 mm swimming pool hose using hose clamps and Teflon tape.

    All Steinbach air heat pumps are equipped with a titanium heat exchanger and can be used for salt water pools with a salt concentration of up to 0.5 %.

    Yes, the air source heat pump is always integrated into the existing filter circuit after the filter system. Note that the filter pump has the required minimum water flow rate.

    The most powerful heating is of no use if the following factors are not taken into account: Pools with a cover, e.g. solar cover, have a lower heat loss. Insulated pools have a much lower heat loss than pools without insulation. The filter runtime and thus the operating time of the additional heating must be taken into account. Wait 24 - 48 h until the set temperature is reached. The higher the temperature difference between the pool water and the outside temperature, the higher the energy loss. Take external influences into account. Heat loss can occur due to cold or strong wind. Minimise the flow rate of the heat pump within the minimum water flow rate of (depending on the heat pump model*) , so that the residence time in the heat pump is longer. *4 m³/h-6 m³/h = 049202, 6 m³/h-8 m³/h = 049207

    The volume of the heat pumps depends on the type and output. You will find the technical data for each individual product. Heat pumps have become increasingly quieter in recent years and are currently between 30 and 40 dB(A). For example, 30dB(A) corresponds to the sound of your own breathing and 40dB(A) to a living room with closed soundproof windows.

    EEb means that the water flow is insufficient. Raise the water flow using a bypass kit that regulates the heat pump.

    EEc means that the ambient temperature is below 15°C. Wait until the ambient temperature increases. In the cold seasons autumn/winter, the heat pump must be dismantled.

    The water that forms in the heat pump is called condensate. This is the moisture contained in the air that condenses when it comes into contact with certain cold components inside the heat pump. The more humid the outside air, the more condensate the heat pump produces (your unit may produce several litres of water per day). The water collects at the bottom of the heat pump and escapes through the drain provided.

    Symbol photos

    The pictures shown are just for reference, the actual product may differ.